HL Dryer for heat shrink sleeves

“GVS-SIL-E SERIES” FIBERGLASS SLEEVE WITH SILICONE RUBBER

The GVS-SIL-E Series expandable sleeve made of fiberglass and covered in silicone rubber is suitable for all uses where it is necessary to protect particular parts, that have an irregular shape, from high temperatures. In fact, the main feature of this sheath is the ability to expand, up to double the initial diameter, adapting perfectly to the component to be protected.

  • Series: Fiberglass with Silicone
  • 1:2 expansion ratio. The sheath expands by 1 times the initial diameter
  • Dielectric Rigidity in Kv: 3.0 – other voltages on request
  • Thermal Class:  C-250°C
  • Available diameters: from 2.0mm to 25.0mm
  • Operating temperature: -60°C to +250°C, with peaks of +290°C
  • Compliant with standards: UL 1441

download the technical data sheet

“PVCWA Series” Openable sleeve in PVC Wrap Around Openable

  • Material: PVC
  • Series: 85°C Wrap Around Openable
  • Field of application: grouping and protection of bundles of electrical cables to be installed or already installed
  • Operating temperature: -15°C to +85°C
  • Color: Grey (Black on request)
  • Operating temperature: -15°C to +85°C
  • Directives: 2002/95/CE RoHS

Delivery Terms

The expected times for order fulfillment are indicated in our Order Confirmation. In urgent cases, by contacting our sales office at the phone number 0373/920659, the shipment of goods can be managed within 24 hours from the date of our order confirmation. For all products not managed in stock, the shipment of goods will be carried out according to the agreements with our sales office.

Delivery

The delivery of goods is ex our warehouse. At the customer's request, our company offers a "Free Domicile with Invoice Charge" service using a shipper contracted with us. For more information regarding delivery, please consult our General Supply Conditions.

Warranty

RTE warrants, during the warranty period, to repair or replace free of charge those parts that, due to poor material quality or workmanship defects, prove to be defective, but only if they have been used in accordance with the provisions in the "Instruction, Use, and Maintenance Manuals", excluding any other damage and liability for direct or indirect damages resulting from improper use.

For more information regarding delivery terms, delivery, and warranty, please consult our General Supply Conditions.

Related products

thermal shrinking sheaths

Frequently Asked Questions

What are the regulations and certifications that an insulating sheath must comply with in order to be used in the railway and/or rail transport sector?
Insulating sheaths, whether they be heat-shrinkable, silicone, braided in polyamide, Wrap Around or fibreglass coated with silicone must comply with EN45545 in order to be used in the railway sector. It is necessary to define the classification level HL1 – HL2 – HL3, together with the risk level, R22 – R23 in order to identify the suitable sheath for each type of use.
What are the differences between the various classification levels, HL1-HL2-HL3 and between the risk levels R22 – R23?
The classification level HL1-HL2-HL3, together with the risk level R22 – R23 define in which area the chosen sheath can be used. Needless to say, a sheath with a maximum classification level, HL3, can be used for all uses where lower classifications such as HL1 – HL2 are required.
CLASSIFICATION LEVEL HL1 – HL2 – HL3
HL1 à A sheath that can be used for surface trains that do not go through tunnels, for example a city tram;

HL2 à A sheath that can be used for surface trains that go through tunnels, for example a normal freight/passenger train and all high-speed trains;


HL3 à A sheath that can be used for trains that run mainly on underground railways, i.e. Subway/Metro;
RISK CLASS R22 – R23
All items that are not found within other lists, (such as, for example, doors, seats, cables, brakes, mattresses etc.) and that have an exposed surface less than or equal to 0.20 m2 belong to the 2 R22 – R23 risk classes. For the sake of convention, heat shrink sheaths are considered to be within these 2 groups.

R23 à The sheath can be used outside the wagon

R22 à The sheath can be used inside the wagon

A sheath with a maximum risk class, R22, can be used for all uses where lower risk classes such as R23 are required.

As a result, since the specifications requiring an R22 risk class are stricter than those requiring an R23 risk class, it follows that if the sheath has an HL3 classification level and an R22 risk class, the sheath in question can be used both outside and inside the wagon.
What are the applications for which sheaths are used that comply with the EN45545 railway sector standard?
Insulating sheaths, compliant with the EN45545 standard for the railway sector, are usually used inside:
Ø WCML + SBB electrical panels
Ø RAILWAY CARRIAGES body interior
What are the main features of sheaths that comply with EN45545?
Ø Operating temperature: -60°C ÷ +250°C
Ø Thermal class: C 250°C
Ø Self-extinguishing
Ø Fire behaviour and determination of fumes and gases; HL3 according to requirement R22-R23 of railway standard EN45545
What are the delivery times for sheaths that comply with the EN45545 standard for the railway sector?
Sheaths compliant with EN45545 are available for immediate delivery