Heat shrink slevve STMT36AS-BUS BAR 36KV

“PVC SERIES 70°C” SELF-EXTINGUISHING PVC SLEEVE

The PVC070 series PVC sleeve has excellent physical and electrical properties. Ideal for general cladding, wiring and insulation applications, the PVC070 sleeve can be used in the most varied industrial sectors such as: Appliances and electrical wiring in general.

  • Series: PVC 70°
  • Available diameters: from 1.0mm to 34.0mm
  • Operating temperature: -20°C to +70°C
  • Conforms to standards: UL94V2, ISO 527, ISO1183, ASTMD570

download the technical data sheet

Fluoropolymer Heat Shrink Tubing “PTFE-AWG Series” – 4:1 Shrink Ratio

  • Material: Fluoropolymer
  • Shrink Ratio: 4:1
  • Application Range: Coating, wiring, and insulation under extreme environmental conditions
  • Color: Transparent
  • Operating Temperature: -70 °C to +260 °C
  • Minimum Shrink Temperature: > +330 °C
  • Melting Temperature: 327 °C according to ASTM D2116
  • Flammability: V0 according to UL 94 – V0
  • Oxygen Index: > 95%
  • Tensile Strength: 29 to 39 N/mm² according to DIN 53455 (at 23 °C)
  • Elongation at Break: 200% to 500% according to DIN 53455 (at 23 °C)
  • Longitudinal Change: ± 10%
  • Density: 2.14 to 2.19 g/cm³ according to DIN 53479
  • Dielectric Strength: 40 to 80 kV/mm according to DIN 53481
  • Volume Resistivity: ≥ 10¹⁸ Ω·cm according to DIN 53482
  • Water Absorption: 0.01%
  • Thermal Conductivity: 0.23 W/m·K (at 23 °C)

Heat Shrinking Instructions

  1. To shrink the heat shrink tubing, use equipment specifically designed for this operation, such as heat guns or hot air tunnels.
  2. Begin shrinking from one end—preferably the most critical area—and proceed slowly toward the opposite end. This method helps prevent the formation of air bubbles between the inner wall of the tubing and the object being covered.
  3. If the object to be covered is made of metal or is a good heat conductor, it is recommended to preheat the object to avoid “cold spots,” allowing for a smooth and perfect fit of the heat shrink tubing.
  4. To prevent overheating of the heat shrink tubing, ensure even heat distribution. Excessive overheating during the shrinking process may cause bubbling, discoloration, and, in some cases, rupture of the tubing.

Delivery Terms

The expected times for order fulfillment are indicated in our Order Confirmation. In urgent cases, by contacting our sales office at the phone number 0373/920659, the shipment of goods can be managed within 24 hours from the date of our order confirmation. For all products not managed in stock, the shipment of goods will be carried out according to the agreements with our sales office.

Delivery

The delivery of goods is ex our warehouse. At the customer's request, our company offers a "Free Domicile with Invoice Charge" service using a shipper contracted with us. For more information regarding delivery, please consult our General Supply Conditions.

Warranty

RTE warrants, during the warranty period, to repair or replace free of charge those parts that, due to poor material quality or workmanship defects, prove to be defective, but only if they have been used in accordance with the provisions in the "Instruction, Use, and Maintenance Manuals", excluding any other damage and liability for direct or indirect damages resulting from improper use.

For more information regarding delivery terms, delivery, and warranty, please consult our General Supply Conditions.

Related products

thermal shrinking sheaths

Frequently Asked Questions

What are the regulations and certifications that an insulating sheath must comply with in order to be used in the railway and/or rail transport sector?
Insulating sheaths, whether they be heat-shrinkable, silicone, braided in polyamide, Wrap Around or fibreglass coated with silicone must comply with EN45545 in order to be used in the railway sector. It is necessary to define the classification level HL1 – HL2 – HL3, together with the risk level, R22 – R23 in order to identify the suitable sheath for each type of use.
What are the differences between the various classification levels, HL1-HL2-HL3 and between the risk levels R22 – R23?
The classification level HL1-HL2-HL3, together with the risk level R22 – R23 define in which area the chosen sheath can be used. Needless to say, a sheath with a maximum classification level, HL3, can be used for all uses where lower classifications such as HL1 – HL2 are required.
CLASSIFICATION LEVEL HL1 – HL2 – HL3
HL1 à A sheath that can be used for surface trains that do not go through tunnels, for example a city tram;

HL2 à A sheath that can be used for surface trains that go through tunnels, for example a normal freight/passenger train and all high-speed trains;


HL3 à A sheath that can be used for trains that run mainly on underground railways, i.e. Subway/Metro;
RISK CLASS R22 – R23
All items that are not found within other lists, (such as, for example, doors, seats, cables, brakes, mattresses etc.) and that have an exposed surface less than or equal to 0.20 m2 belong to the 2 R22 – R23 risk classes. For the sake of convention, heat shrink sheaths are considered to be within these 2 groups.

R23 à The sheath can be used outside the wagon

R22 à The sheath can be used inside the wagon

A sheath with a maximum risk class, R22, can be used for all uses where lower risk classes such as R23 are required.

As a result, since the specifications requiring an R22 risk class are stricter than those requiring an R23 risk class, it follows that if the sheath has an HL3 classification level and an R22 risk class, the sheath in question can be used both outside and inside the wagon.
What are the applications for which sheaths are used that comply with the EN45545 railway sector standard?
Insulating sheaths, compliant with the EN45545 standard for the railway sector, are usually used inside:
Ø WCML + SBB electrical panels
Ø RAILWAY CARRIAGES body interior
What are the main features of sheaths that comply with EN45545?
Ø Operating temperature: -55°C ÷ +105°C
Ø Shrinkage 2÷1
Ø Fire behaviour and determination of fumes and gases; HL3 according to requirement R22-R23 of railway standard EN45545
Ø Tensile strength: 10N MM2
Ø Elongation at breakage: 200%
What are the delivery times for sheaths that comply with the EN45545 standard for the railway sector?
Sheaths compliant with EN45545 are available for immediate delivery